LS iC5 Fault Codes List
Troubleshoot your LS iC5 (Starvert) inverter with our updated guide. Learn to interpret OCT, OVT, and ETH trips, access fault history via the H-group, and reset faults.
LS iC5 Fault Codes Reference Table
Below is the complete list of protective functions and alarm codes. Please refer to this table to match the code on your LED display with the specific hardware or load issue.
LS iC5 Fault Codes List
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| OC Overcurrent |
Cause:
Remedy:
|
| GF Ground fault current |
Cause:
Remedy:
|
| IOL Inverter Overload |
Cause:
Remedy:
|
| OLT Overload trip |
Cause: The inverter turns off its output if the output current flows at 150% of rated current for more than the current limit time (1 min). Remedy:
|
| OHT Heat sink overheat |
Cause:
Remedy:
|
| COL DC link capacitor overload |
Cause: The inverter has determined it is time to replace the old DC link capacitor. Remedy:
|
| POT Output Phase loss |
Cause:
Remedy:
|
| OVT Over voltage |
Cause:
Remedy:
|
| LVT Low voltage |
Cause:
Remedy:
|
| ETH Electronic Thermal |
Cause:
Remedy:
|
| EEP Parameter save error |
Cause: User-setting parameters failed to be entered into memory. Remedy:
|
| H/W Inverter hardware fault |
Cause: An error occurred in the control circuitry of the inverter. Remedy:
|
| Err Communication Error |
Cause: The inverter cannot communicate with the keypad. Remedy:
|
| FAN Cooling fan fault |
Cause:
Remedy:
|
| EST Instant cut off |
Cause: Used for emergency stop. The EST terminal has been turned on. Remedy:
|
| EtA External fault A contact input |
Cause: The terminal set to "18 (External fault-A)" in I20-I24 group is ON. Remedy:
|
| EtB External fault B contact input |
Cause: The terminal set to "19 (External fault-B)" in I20-I24 group is ON. Remedy:
|
| --L Operating method lost |
Cause: No frequency command is applied to V1 and I when operation is set via Analog input. Remedy:
|
How to Read iC5 Faults via the Keypad
The iC5 is built for simplicity. In 2026, the on-board keypad and the built-in potentiometer remain the primary ways to interact with the drive. To diagnose a trip, navigate to the following parameter groups:
- Current Fault: When the drive trips, the display immediately alternates between the trip code and the operating frequency. Do not reset until you have noted the code.
- Fault History (H1 to H5): The iC5 stores the last 5 trips. Navigate to the H (Function Group 2) group. Parameters H 1 through H 5 display the history in order of occurrence.
- Fault Conditions: Within the H-group history, pressing the ENT key allows you to view the frequency and operating status (accel, decel, or constant speed) that was present when the trip occurred.
General Troubleshooting Steps
Perform these hardware checks before attempting to clear a major trip on an iC5 drive:
- Overcurrent (OCT): This is the most common trip. Check if the “Torque Boost” (Parameter F27) is set too high for the motor. Also, verify that the motor leads are not grounded or shorted.
- Overload (ETH): Electronic Thermal Trip. Ensure the motor’s rated current is set correctly in parameter H33. If the motor is running at low speeds without a specialized cooling fan, it may overheat even at rated current.
- Overvoltage (OVT): High DC link voltage. Usually occurs during deceleration. If the load has high inertia, you must increase the Deceleration Time (Parameter dEC) or use the “Stall Prevention” function.
Frequently Asked Questions (FAQ)
Q: What is the difference between “LVT” and “OCT”?
A: LVT (Low Voltage Trip) occurs when the input AC power drops below the allowable level, often due to a poor power grid or loose wiring. OCT (Overcurrent Trip) is a safety shutdown caused by an electrical spike on the output side, usually a short circuit or a jammed motor.
Q: How do I reset a fault on the LS iC5?
A: Once the cause is resolved, you can reset the drive by:
- Pressing the STOP/RESET key on the keypad.
- Closing the digital input terminal assigned to the RST (Reset) function (often terminal P3, P4, or P5 depending on configuration).
- Cycling the main input power (Wait for the display to turn off fully, then re-apply power).
Q: Why does my drive show “POT”?
A: POT is not a fault; it indicates that the drive is configured to receive its frequency reference from the built-in Potentiometer (the dial on the front). If you want to use the keypad arrows instead, you must change parameter Frq to ‘0’.
Q: What does “GFT” mean?
A: GFT stands for Ground Fault Trip. The drive has detected an imbalance in the output phases, meaning current is leaking to the earth. Check the motor windings and the insulation of the cables immediately.