A5A0 Safe Torque Off (STO) Warning in ABB ACS880 Drive
A5A0 Safe Torque Off (STO) Warning in ABB ACS880 Drive indicates that the Safe Torque Off (STO) function is active because one or both safety circuit signals connected to connector XSTO have been lost. When STO is activated, the drive prevents torque-producing power from being supplied to the motor, ensuring safe operation.
This warning is controlled by the programmable parameter:
31.22 – STO Indication Run/Stop
Possible Causes:
- Safe Torque Off circuit is intentionally activated.
- Emergency stop button has been pressed.
- Safety relay output is open.
- Safety gate or safety interlock is open.
- Broken wiring in the STO circuit.
- Loose connection at the XSTO connector.
- Faulty safety relay.
- Faulty emergency stop device.
- Incorrect STO wiring.
- Maintenance lockout/tagout procedure in effect.
- Safety PLC has removed the STO signal.
- Incorrect configuration of the safety circuit.
Solutions:
- Check the safety circuit connections connected to the XSTO connector.
- Verify that the emergency stop pushbutton is in the normal position.
- Check the safety relay and confirm its outputs are active.
- Inspect safety gate switches and interlocks.
- Verify continuity of STO wiring.
- Check for loose or damaged wires at the XSTO connector.
- Ensure all safety devices are operating correctly.
- Verify the safety PLC outputs (if used).
- Inspect the STO circuit for wiring errors.
- Review the configuration of:
Parameter 31.22 – STO Indication Run/Stop
- Restore the safety circuit and restart the drive if required.
Additional Information
The Safe Torque Off (STO) function is a certified safety feature that removes the drive's ability to generate motor torque without disconnecting power from the drive.
When STO is active:
- Motor torque generation is disabled.
- The motor coasts to a stop.
- The drive remains powered.
- Restart is not possible until the STO circuit is restored.
Typical devices connected to the STO circuit include:
- Emergency stop pushbuttons.
- Safety relays.
- Safety PLCs.
- Guard door switches.
- Machine safety interlocks.
Recommended Troubleshooting Sequence
- Check whether an emergency stop has been activated.
- Inspect the STO safety relay.
- Verify safety gate and interlock status.
- Check XSTO connector wiring.
- Confirm STO input signals are present.
- Review Parameter 31.22 settings.
- Restore the safety circuit.
- Restart the drive if required.
Relevant Parameter
| Parameter | Description |
|---|---|
| 31.22 | STO Indication Run/Stop |
Related Faults and Warnings
| Code | Description |
|---|---|
| A5A0 | STO Warning |
| 5091 | Safe Torque Off Fault |
Proper maintenance of the safety circuit, STO wiring, and safety devices will help prevent recurring A5A0 Safe Torque Off Warnings in ABB ACS880 drives while ensuring safe machine operation.