Delta ASDA-A+ Fault Codes Reference Table
Use the search bar below or browse the table to identify your specific error code.
ASDA-A&A+ Series Troubleshooting
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| ALE01 Overcurrent |
Cause:
Remedy:
|
| ALE02 Overvoltage |
Cause:
Remedy:
|
| ALE03 Undervoltage |
Cause:
Remedy:
|
| ALE05 Regeneration error |
Cause:
Remedy:
|
| ALE06 Overload |
Cause:
Remedy:
|
| ALE07 Overspeed |
Cause:
Remedy:
|
| ALE08 Abnormal pulse control command |
Cause:
Remedy:
|
| ALE09 Excessive deviation |
Cause:
Remedy:
|
| ALE10 Watch dog execution time out |
Cause:
Remedy:
|
| ALE11 Encoder error (Position detector fault) |
Cause:
Remedy:
|
| ALE12 Adjustment error |
Cause:
Remedy:
|
| ALE13 Emergency stop activated |
Cause:
Remedy:
|
| ALE14 Reverse (CWL) limit switch error |
Cause:
Remedy:
|
| ALE15 Forward (CCWL) limit switch error |
Cause:
Remedy:
|
| ALE16 IGBT temperature error |
Cause:
Remedy:
|
| ALE17 Memory error |
Cause: Data error in Memory read-out / write-in. Remedy: If the error does not clear after resetting the power supply, please contact your distributor for assistance or contact with Delta. |
| ALE18 DSP communication error |
Cause: Control power is in error. Remedy: If the error does not clear after resetting the power supply, please contact your distributor for assistance or contact with Delta. |
| ALE19 Serial communication error |
Cause:
Remedy:
|
| ALE20 Serial communication time out |
Cause:
Remedy:
|
| ALE21 Command write-in error |
Cause: Control power is in error. Remedy: If the error does not clear after resetting the power supply, please contact your distributor for assistance or contact with Delta. |
| ALE22 Input power phase loss |
Cause: Control power supply is in error. Remedy: If the fault does not clear even when the three-phase power is connected correctly, please contact your distributor for assistance or contact with Delta. |
| ALE23 Pre-overload warning |
Cause: The drive is going to overload. Remedy:
|
| ALE97 Internal command execution time out |
Cause: An error occurs when internal command is executing. Remedy: If the error does not clear after resetting the power supply, please contact your distributor for assistance or contact with Delta. |
| ALE98 DSP communication error |
Cause: Maybe the hardware is damaged. Remedy: If the error does not clear after resetting the power supply, please contact your distributor for assistance or contact with Delta. |
| ALE99 DSP communication error |
Cause: Maybe the hardware is damaged. Remedy: If the error does not clear after resetting the power supply, please contact your distributor for assistance or contact with Delta. |
| ALE04 "Mismatch" error |
Cause: The type of the servo motor is incorrect. Remedy: Repair or replace the servo drive or the servo motor. |
| ALE24 Encoder error (Position detector fault) |
Cause: Maybe the Encoder is damaged. Remedy: If the error does not clear after resetting the power supply, please contact your distributor for assistance or contact with Delta. |
| ALE25 Encoder error (Position detector fault) |
Cause: The servo drive automatically detect the servo motor is in error. Remedy:
|
How to Read ASDA-A+ Faults via Keypad & ASDA-Soft
Troubleshooting the ASDA-A+ differs from the standard A-Series primarily in how feedback is handled. In 2026, using the correct tools is vital to distinguishing between noise and hardware failure:
- ASDA-Soft (PC Tool): Connect via the CN3 port.
- Scope Function: Because the ASDA-A+ handles high-resolution feedback, it is more sensitive to “Gain” settings. Use the digital scope to monitor Position Error. If the drive trips on AL009 (Deviation Too Large), the scope will show if the motor is lagging due to mechanical binding or if the Electronic Gear Ratio (P1-44/45) is set incorrectly for the high-res encoder.
- Keypad Monitoring: The display is your first line of defense.
- Feedback Check: Press MODE to view the feedback pulse count. On an ASDA-A+, rotating the shaft one revolution should result in a massive number change (1,280,000 counts) compared to the standard A-Series (10,000 counts). If the numbers don’t change or jump erratically, your encoder or cable is damaged.
Frequently Asked Questions (FAQ)
Q: What is the main difference between ASDA-A and ASDA-A+ faults?
A: While the AL codes are largely the same, the cause often differs:
- Tuning Faults (AL006/AL009): The ASDA-A+ is far more sensitive. Old mechanical systems with backlash that worked on an ASDA-A might cause resonance (vibration) and overload faults on an ASDA-A+ due to the higher stiffness required by the high-res encoder.
Q: How do I fix “AL011” (Encoder Error) on the A+ Series?
A:
- Cable: The high-resolution signal is sensitive to noise. Ensure the CN2 cable is shielded and separated from the power cable.
- Motor Compatibility: Verify the motor model ends in a code supported by the A+ drive. You cannot plug a standard 2500ppr motor into an A+ drive configured for 20-bit absolute mode without changing parameters.
Q: How do I reset a Delta ASDA-A+ fault?
A:
- Digital Input: Toggle the input configured for ARST (Alarm Reset).
- Keypad: Locate the Reset parameter or hold the SET key on the alarm screen.
- Power Cycle: Required for major hardware faults like AL001 (Overcurrent) or AL003 (Undervoltage).