Schneider ATV320 Drive Fault Codes
Complete reference list of Schneider Altivar Machine 320 (ATV320) fault codes. Learn to interpret LED errors like CFF, STO/PRA, and OCF on Compact and Book drives.
This guide provides the most updated reference data for 2026 to help you navigate the specific “Machine” faults and safety interlocks of the ATV320 series.
Schneider ATV320 Fault Codes Reference Table
Schneider ATV320 Fault Codes Reference Table
Schneider ATV320 Fault Codes Reference Table
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| AnF [Load slipping] |
Cause: The difference between the output frequency and the speed feedback is not correct. Remedy:
|
| ASF [Angle Error] |
Cause: This occurs during the phase-shift angle measurement, if the motor phase is disconnected or if the motor inductance is too high. Remedy:
|
| bLF [Brake control] |
Cause: Brake release current not reached. Brake engage frequency threshold [Brake engage freq] (bEn) only regulated when brake logic control is assigned. Remedy:
|
| brF [Brake feedback] |
Cause: The brake feedback contact does not match the brake logic control. The brake does not stop the motor quickly enough. Remedy:
|
| CrF1 [Precharge] |
Cause: Charging relay control detected fault or charging resistor damaged. Remedy:
|
| EEF1 [Control Eeprom] |
Cause: Internal memory detected fault, control block. Remedy:
|
| EEF2 [Power Eeprom] |
Cause: Internal memory detected fault, power card. Remedy:
|
| FCF1 [Out. contact. stuck] |
Cause: The output contactor remains closed although the opening conditions have been met. Remedy:
|
| HdF [IGBT desaturation] |
Cause: Short-circuit or grounding at the drive output. Remedy:
|
| ILF [internal com. link] |
Cause: Communication interruption between option card and drive. Remedy:
|
| InF1 [Rating error] |
Cause: The power card is different from the card stored. Remedy:
|
| InF2 [Incompatible PB] |
Cause: The power card is incompatible with the control block. Remedy:
|
| InF3 [Internal serial link] |
Cause: Communication interruption between the internal cards. Remedy:
|
| InF4 [Internal-mftg zone] |
Cause: Internal data inconsistent. Remedy:
|
| InF6 [Internal - fault option] |
Cause: The option installed in the drive is not recognized. Remedy:
|
| InF9 [Internal- I measure] |
Cause: The current measurements are incorrect. Remedy:
|
| InFA [Internal-mains circuit] |
Cause: The input stage is not operating correctly. Remedy:
|
| InFb [Internal- th. sensor] |
Cause: The drive temperature sensor is not operating correctly. Remedy:
|
| InFE [internal- CPU] |
Cause: Internal microprocessor detected fault. Remedy:
|
| SAFF [Safety fault] |
Cause:
Remedy:
|
| SOF [Overspeed] |
Cause: Instability or driving load too high. Overspeed threshold has been reached. Remedy:
|
| SPF [Speed fdback loss] |
Cause: Signal on "Pulse input" missing, or Encoder feedback signal missing. Remedy:
|
| CnF [Com. network] |
Cause: Communication interruption on communication card. Remedy:
|
| CoF [CANopen com.] |
Cause: Communication interruption on the CANopen® bus. Remedy:
|
| EPF1 [External flt-LI/Bit] |
Cause: Event triggered by an external device, depending on user. Remedy:
|
| EPF2 [External fault com.] |
Cause: Event triggered by a communication network. Remedy:
|
| FbES [FB stop flt.] |
Cause: Function blocks have been stopped while motor was running. Remedy:
|
| FCF2 [Out. contact. open.] |
Cause: The output contactor remains open although the closing conditions have been met. Remedy:
|
| LCF [input contactor] |
Cause: The drive is not turned on even though [Mains V. time out] (LCt) has elapsed. Remedy:
|
| LFF3 [AI3 4-20mA loss] |
Cause: Loss of the 4-20 mA reference on analog input AI3. Remedy:
|
| ObF [Overbraking] |
Cause: Braking too sudden or driving load too high. Supply voltage too high. Remedy:
|
| OCF [Overcurrent] |
Cause:
Remedy:
|
| OHF [Drive overheat] |
Cause: Drive temperature too high. Remedy:
|
| OLC [Proc. overload flt] |
Cause: Process overload. Remedy:
|
| OLF [Motor overload] |
Cause: Triggered by excessive motor current. Remedy:
|
| OPF1 [1 output phase loss] |
Cause: Loss of one phase at drive output. Remedy:
|
| OPF2 [3 motor phase loss] |
Cause:
Remedy:
|
| OSF [Mains overvoltage] |
Cause: Supply voltage too high. Disturbed mains supply. Remedy:
|
| OtFL [LI6=PTC overheat] |
Cause: Overheating of PTC probes detected on input LI6. Remedy:
|
| PtFL [LI6=PTC probe] |
Cause: PTC probe on input LI6 open or short-circuited. Remedy:
|
| SCF1 [Motor short circuit] |
Cause: Short-circuit or grounding at the drive output. Remedy:
|
| SCF3 [Ground short circuit] |
Cause: Significant earth leakage current at the drive output if several motors are connected in parallel. Remedy:
|
| SCF4 [IGBT short circuit] |
Cause: Power component detected fault. Remedy:
|
| SCF5 [Motor short circuit] |
Cause: Short-circuit at drive output. Remedy:
|
| SLF1 [Modbus com.] |
Cause: Communication interruption on the Modbus bus. Remedy:
|
| SLF2 [PC com.] |
Cause: Communication interruption with PC Software. Remedy:
|
| SLF3 [HMI com.] |
Cause: Communication interruption with the graphic display terminal or remote display terminal. Remedy:
|
| SSF [Torque/current lim] |
Cause: Switch to torque or current limitation. Remedy:
|
| tJF [IGBT overheat] |
Cause: Drive overheated. Remedy:
|
| tnF [Auto-tuning] |
Cause: Special motor, motor power unsuitable, not connected, or not stopped. Remedy:
|
| ULF [Proc. underload Flt] |
Cause: Process underload. Remedy:
|
| CFF [Incorrect config.] |
Cause: Option card changed or removed. Control block replaced by a control block configured on a drive with a different rating. Remedy:
|
| CFI [Invalid config.] |
Cause: Invalid configuration. The configuration loaded is inconsistent. Remedy:
|
| CFI2 [Download invalid] |
Cause: Interruption of download operation. Remedy:
|
| CSF [Ch. Sw. fault] |
Cause: Switch to not valid channels. Remedy:
|
| dLF [Dynamic load fault] |
Cause: Abnormal load variation. Remedy:
|
| FbE [FB fault] |
Cause: Function blocks error. Remedy:
|
| HCF [Cards pairing] |
Cause: The [CARDS PAIRING] (PPI-) function has been configured and a drive card has been changed. Remedy:
|
| PHF [Input phase loss] |
Cause: Drive incorrectly supplied, fuse blown, phase missing, or unbalanced load. Remedy:
|
| USF [Undervoltage] |
Cause: Supply mains too low. Transient voltage dip. Remedy:
|
| InIt [Initialization in progress] |
Description: The microcontroller is initializing. Search underway for communication configuration. |
| Com.E (Flashing) [Communication error] |
Description: Time out detected fault (50 ms). This message is displayed after 20 attempts at communication. |
| A-17 (Flashing) [Alarm button] |
Description: A key has been held down for more than 10 seconds. The keypad is disconnected or woke up while a key is pressed. |
| cLr (Flashing) [Confirmation of detected fault reset] |
Description: This is displayed when the STOP key is pressed once if the active command channel is the remote display terminal. |
| dEU.E (Flashing) [Drive disparity] |
Description: The drive brand does not match that of the remote display terminal. |
| rOM.E (Flashing) [ROM anomaly] |
Description: The remote display terminal detects a ROM anomaly on the basis of checksum calculation. |
| rAM.E (Flashing) [RAM anomaly] |
Description: The remote display terminal detects a RAM anomaly. |
| CPU.E (Flashing) [Other detected faults] |
Description: Other detected faults. |
How to Read ATV320 Faults & History
Navigating the ATV320 with the integrated “Jog Dial” can be tricky. Here is how to find critical diagnostics:
- Safety Status (STO / PRA): The most common “issue” calls are actually safety statuses.
- STO: Safe Torque Off. The drive is healthy but the safety circuit is open.
- PRA: Power Removal Active. This is the legacy code for STO found on older firmware versions.
- Fault History: Unlike older drives, the integrated LED display does not show a full fault history list by default.
Best Practice for 2026: Use the Schneider SoMove software (via USB-C or Modbus) or plug in a remote Graphic Display Terminal (VW3A1111) to view the “Error History” log with timestamps. - Active Faults: Active faults flash on the screen. Press the ENT (Jog Dial) to view the “Error Code” (e.g., OCF) and press it again to potentially see the “Sub-code” if applicable.
Frequently Asked Questions (FAQ)
Q: What is “CFF” (Incorrect Configuration)?
A: This typically appears when a drive is replaced or an option module is removed.
Cause: The configuration saved in the drive’s memory does not match the connected hardware (Power board or Option Card).
Fix:
1. Go to CONF → FCS- (Factory Settings).
2. Select FrY- (Parameter Group List) and set to ALL.
3. Select GFS (General Factory Settings) and set to YES (Hold for 2 seconds).
Warning: This wipes all programming.
Q: The drive flashes “SS1” or “SLS”. What does this mean?
A: These are Safety Functions.
SS1: Safe Stop 1 (Monitored Deceleration).
SLS: Safely Limited Speed.
The
drive is not faulted, but it is restricting operation because a safety
condition has been triggered. Check your safety PLC or safety inputs
(logic settings in the Sjt menu).
Q: How do I fix “OCF” (Overcurrent) on an ATV320?
A:
1. Motor Data: Ensure the nPr (Rated Power) and nCr (Rated Current) in the drC- menu match the motor nameplate exactly.
2. Control Law: If using “Ctt = Std” (Standard V/f), try switching to “Perf” (Vector Control) and performing an Autotune (tUn).
3. Mechanical: Check for a jammed load or a brake that hasn’t released.